Temperature Measurement System MESY©
USB-Temperature measurement system 570.70 Mesy III
Save and real time temperature measurement system with 3 thermocouples and USB-interface
Specific notes | |
---|---|
Dimensions: | 120 x 70 x 23 mm (LxWxH) |
Weight: | approx. 170 g |
Measurement rage: | 0 - 400 °C |
Down Load PDF file SEF GmbH = Mesy III.pdf
The new measurement system 570.70 is based on the long experience with our previous
models 570.20 and 570.35, but takes care of nowadays technological standards.
It is absolutely necessary to document the melting process to guarantee nowadays requirements
concerning the DIN ISO and constant manufacturing quality.
Therefore our MESY© 570.70 offers ideal options.
The MESY© will be connected directly with a PC via the USB-interface. This interface is used for
the data exchange and also for the voltage supply, so no additional battery is needed.
For the measurement 3 channels are available. The NiCr/Ni thermocouples are included in the delivery.
They offer enough length, so that the MESY© can stay outside the soldering system during the measurement.
The measured temperatures are shown in real time on the PC.
Now mathematic editing is possible. Auf vielfachen Wunsch unserer Kunden werden die
Temperaturen nicht nur grafisch gargestellt, sondern sie werden zusätzlich mit den dazugehörigen
Zeiwerten in eine Microsoft Excel Tabelle transferiert. So ist auch eie mathematische Bearbeitung bzw.
der Trasfer in andere Microsoft Office-Programme möglich.
Down Load PDF file SEF GmbH =
Of course it is also possible to print out the soldering profile for documentation.
The MESY© offers also the possibility to store a once measured temperature curve as a reference curve
and equip it with a tolerance range.
For later control measurements during the series manufacturing this reference curve can be used for comparison
. So you can make sure, that you are manufacturing in the middle of the process range with reserves to both sides.
Further analysis values are the time under and over apreconfigured melting temperature, the maximum peak temperature
and the maximum rate of growth.
For the measurement the measure intervals can be preconfigured in steps from 500 ms up to 30 m.
Each measurement is limited to 3000 measurement points.
Systemvoraussetzungen: Windows ME/2000/XP mit Excel 2000/XP
(Messsysteme mit Software für ältere Betriebsysteme auf Anfrage)
Options:
571.50 NiCr/Ni-K 0,5 m sensor
571.51 NiCr/Ni-K 1,5 m sensor
571.52 NiCr/Ni-K 2,0 m sensor
571.53 NiCr/Ni-K 3,0 m sensor
MESY 570.77
Temperature Measurement System MESY©
USB-Temperature Measurement System 570.77
Save temperature measurement system with 3 thermocouples and USB-interface
Specific notes | |
---|---|
Dimensions: | 115 x 85 x 9,5 mm (LxWxH) |
Weight: | approx. 165 g |
Measurement range: | 10 - 400 °C |
Our newest measurement system 570.77 is a continuos further development of our USB-MESY© 570.70.
The recording of the measurement values proceeds in storage mode.
The included software runs under the operating system Windows 98 or higher.
The analysation of the data can be done in graphic or in table form.
The installed lithium polymer accumulator has a capacity of approx. 15 hours.
Parameter setting and analysation can be done with a PC.
The storage occurs in the adjusted interval, afterwards the values are transfered to a PC via the USB interface.
The accumulator can be loaded cia the USB-interface or via an external mains
Profiler Set 570.80
ESY Profiler set with 570.77 and 571.77
Thermo insulating box 571.77 and Mesy 570.77 is also available as set 570.80 .
Specific notes 571.77 | |
---|---|
Dimensions: | 30 x 160 x 110 mm (lxwxh) |
Weight: | approx. 700 g |
Insulating attributes at 190 °C out side temperature (at 300 °C) |
approx. 13 min. inner temperature of 60 °C is reached (7,5 min.) |
'15. 온도 프로화일러 > 15-1. 570-77A_SEF' 카테고리의 다른 글
570-77 온도 프로화일러 사진으로 보기 (0) | 2022.04.25 |
---|---|
Real time 온도 프로화일러. 독일 SEF GmbH (0) | 2022.04.25 |
Mesy III 온도 프로화일러, Tempearture Profiler SEF GmbH (0) | 2009.11.27 |
"KIC" Asia area 에서 성공한 이유. 6 Year ago meet at ShenZhen (0) | 2009.08.21 |
temperature Profiler SEF GmbH [Mesy III. 570-77 2 type] (0) | 2009.07.15 |